Skip to main content

Table 6 System parameters

From: Discrete space vector modulation and optimized switching sequence model predictive control for three-level voltage source inverters

 

Parameter

Grid-Connected

Simulation

Experimental

Vdc

DC-link voltage

800 V

110 V

\({E}_{m}\)

Line-line voltage (RMS)

\({380} \,\)V

\({50}\) V

C

DC link capacitors

500 μF

2200 μF

f

Fundamental frequency

50 Hz

50 Hz

R

Resistance

0.1 Ω

0.5 Ω

Iref

Reference current

15/30 A

3/6 A

L

Filter inductance

5 mH

7 mH