Skip to main content

Table 5 Rules for selecting the optimal control voltage

From: Discrete space vector modulation and optimized switching sequence model predictive control for three-level voltage source inverters

The output voltage vector

boundaries

Duty cycle

A type

B type

dux

duy

duz

ux

ΔL1 ≤ − 3

ΔL2 ≤ − 3

1

0

0

uy

ΔL3 ≥ 3

ΔL3 ≤ − 3

0

1

0

uz

ΔL2 ≥ 3

ΔL1 ≥ 3

0

0

1

uv1

− 3 < ΔL1 ≤ − 1

ΔL2 ≤ 0

ΔL3 ≤ 0

ΔL1 ≤ 0

− 3 < ΔL2 ≤ − 1

0 < ΔL3

2/3

1/6

1/6

uv2

ΔL1 ≤ 0

ΔL2 ≤ − 1

0 < ΔL3

ΔL1 ≤ − 1

ΔL2 < 0

ΔL3 ≤ 0

1/2

1/2

0

uv3

ΔL1 ≤ 0

0 < ΔL2

ΔL3 ≤ − 1

0 < ΔL1

ΔL2 ≤ 0

1 < ΔL3

1/2

0

1/2

uv4

− 1 < ΔL1 < 1

− 1 < ΔL2 < 1

− 1 < ΔL3 < 1

− 1 < ΔL1 < 1

− 1 < ΔL2 < 1

− 1 < ΔL3 ≤ 1

1/3

1/3

1/3

uv5

0 < ΔL1

ΔL2 ≤ 0

1 ≤ ΔL3 < 3

ΔL1 ≤ 0

0 ≤ ΔL2

− 3 ≤ ΔL3 ≤ − 1

1/6

2/3

1/6

uv6

0 < ΔL1

1 ≤ ΔL2 < 3

ΔL3 ≤ 0

1 ≤ ΔL1 < 3

0 < ΔL2

0 < ΔL3

1/6

1/6

2/3

uv7

1 ≤ ΔL1

0 < ΔL2

0 < ΔL3

0 < ΔL1

1 ≤ ΔL2

ΔL3 ≤ 0

0

1/2

1/2