Skip to main content

Table 2 Parameters of the drive system

From: A new ensemble-based classifier for IGBT open-circuit fault diagnosis in three-phase PWM converter

Comment Value
DC-link voltage Udc 700 V
Stator resistance Rs 0.435 Ω
Stator leakage inductance Lls 4 mH
Rotor resistance Rr 0.816 Ω
Rotor leakage inductance Llr 2 mH
Mutual inductance Lm 69.31 mH
Rated speed nrate 2000(r/min)
Rated output power Prate 11 kW
Number of the pole pairs 2