Table 2 Parameters of the simulated MMC

From: Loss distribution analysis and accurate calculation method for bulk-power MMC

Parameters

Value

Rated Capacity/MVA

1000

Rated DC voltage/kV

 ± 350

Rated voltage on grid side/kV

525

Rated voltage on valve side/kV

375

Ratio of converter transformer

525/375

Number of SMs

468

Number of redundant SMs

40

Arm inductor L/mH

115

SM capacitor C/mF

12

Control frequency/kHz

10