Skip to main content

Table 1 The operation parameters of the IES

From: Two-stage distributionally robust optimization-based coordinated scheduling of integrated energy system with electricity-hydrogen hybrid energy storage

Devices

Parameters

Value

DN

\(P_{{{\text{DN\_buy}}}}^{\max }\)/kW

1200

ES

\(P_{{{\text{ES\_ch}}}}^{\max }\)/kW

200

\(P_{{{\text{ES\_dis}}}}^{\max }\)/kW

200

\(C_{{{\text{ES}}}}^{0}\)/kWh

500

\(C_{{{\text{ES}}}}^{\min }\)/kWh

100

\(C_{{{\text{ES}}}}^{\max }\)/kWh

900

\(\eta_{{{\text{ES}}}}\)

0.98

EL

\(P_{{{\text{EL}}}}^{\max }\)/kW

1000

\(\eta_{{{\text{EL}}}}\)

0.8

HS

\(C_{{{\text{HS}}}}^{0}\)/kWh

5000

\(C_{{{\text{HS}}}}^{\min }\)/kWh

1000

\(C_{{{\text{HS}}}}^{\max }\)/kWh

9000

\(\eta_{{{\text{HS}}}}\)

0.95

PEMFC

\(P_{{{\text{PEMFC}}}}^{\max }\)/kW

300

\(\eta_{{{\text{PEMFC}}}}^{{{\text{Ele}}}}\)

0.5

\(\eta_{{{\text{PEMFC}}}}^{{{\text{Ther}}}}\)

0.35

GN

\(P_{{{\text{GN\_buy}}}}^{\max }\)/kW

1200

GB

\(P_{{{\text{GB}}}}^{\max }\)/kW

800

\(\eta_{{{\text{GB}}}}\)

0.96

EB

\(P_{{{\text{EB}}}}^{\max }\)/kW

1000

\(\eta_{{{\text{EB}}}}\)

0.938