Skip to main content

Table 3 Performance indices of different control methods (random power fluctuation scenario)

From: Adaptive H event-triggered load frequency control in islanded microgirds with limited spinning reserve constraints

Control schemes

\(S_{\Delta f}^2 \) (Hz2)

Triggered times

IAE (Hz·s)

Proposed method

0.0053

156

0.05662

PTC without considering saturations [27]

0.0045

1000

0.05350

PTC considering saturations [26]

0.0045

1000

0.05393

FTETC without considering saturations [23]

0.0058

213

0.06031

FTETC considering saturations

0.0062

163

0.06307

UAETC without considering saturations [25]

0.0061

93

0.06028

UAETC considering saturations

0.0063

75

0.06400