Skip to main content

Table 4 Reductions in \({\Delta \text{F}}_{1}\), \({\Delta \text{F}}_{2}\) and \({\Delta \text{P}}_{12}\) deviations due to 3 step load changes using COA

From: Effective participation of wind turbines in frequency control of a two-area power system using coot optimization

Optimizer

\({\Delta \text{F}}_{1}\)

\({\Delta \text{F}}_{2}\)

\({\Delta \text{P}}_{12}\)

1st (%)

2nd (%)

3rd (%)

1st (%)

2nd (%)

3rd (%)

1st (%)

2nd (%)

3rd (%)

PSO

4.30

6.16

4.48

5.97

19.53

14.52

28.10

10.23

16.73

WCA

21.15

25.02

23.13

–

10.48

4.84

80.27

53.42

63.49

HBA

–

–

–

44.78

30.85

38.71

51.08

49.99

47.68

AOS

–

–

–

25.37

32.29

25.81

0.54

7.38

12.92