Skip to main content

Table 5 Steady-state response of different MPPT approaches under study

From: Novel Lyapunov-based rapid and ripple-free MPPT using a robust model reference adaptive controller for solar PV system

Shading Pattern

Technique

Power at MPP (W)

Voltage at MPP (V)

Current at MPP (A)

Pattern 1

(1000,1000,1000 W/m2)

P&O

842.3

112.00

7.52

ANFIS

930.5

114.03

8.16

LRMRAC (Proposed)

998.0

119.37

8.36

Pattern 2

(500, 400, 700 W/m2)

P&O

334.4

68.10

4.91

ANFIS

409.9

80.37

5.10

LRMRAC (Proposed)

448.1

83.60

5.36

Pattern 3

(100, 100, 200 W/m2)

P&O

45.21

26.24

1.72

ANFIS

59.73

33.31

1.79

LRMRAC (Proposed)

115.77

67.31

1.72

Pattern 4

(1000, 700, 500 W/m2)

P&O

340.8

39.17

8.70

ANFIS

490.9

58.86

8.34

LRMRAC (Proposed)

540.3

63.41

8.52