Skip to main content

Table 8 Quantitative analysis for DC-bus voltage

From: Robust backstepping global integral terminal sliding mode controller to enhance dynamic stability of hybrid AC/DC microgrids

Transient time (s)

Settling time (ms)

Overshoot/undershoot (%)

Existing

Proposed

Proposed

Existing

2

35

70

0.10

0.156

4.5

100

200

0.32

0.468

5

42

120

0.26

0.3125

6

100

205

0.42

0.625

6.5

90

170

0.35

0.468

8

50

130

0.27

0.3125