Skip to main content

Table 7 Comparison of the proposed method with similar methods based on MCS and MVS

From: A robust principal component analysis-based approach for detection of a stator inter-turn fault in induction motors

 

Comparative aspects

 

Analyzing domain

The required signals

Delay time (s)

Average accuracy percentage (%)

Robustness to voltage quality problems

[42]

t

I-V

0.02

79

Yes

[19]

t-f

I-V

0.01

81

Yes

[16]

t-f

I

0.02

84

No

[17]

t-f

I

0.02

90

No

Proposed method

t-f

I-V

0.02

94

Yes