Table 4 Controller parameters for the HGS

From: Adaptive coordination control strategy of renewable energy sources, hydrogen production unit, and fuel cell for frequency regulation of a hybrid distributed power system

Parameter

KP

KI

KD

Frequency regulation control parameters (PID-mMSO) [7]

1.9069

1.8844

1.9235

Proposed Kn control parameters

5.1986

0.7925

–