Table 1 Features of typical engineering projects

From: Application and development of ground source heat pump technology in China

Name of projects

GSHP type

Capacity (MW)

Building area (m2)

Beijing Jiahe liyuan

Groundwater heat pump

–

70,000

Tianjin Meijiang ecological community

Ground-coupled heat pump

0.32

3715

Beijing Tianchuang Shiyuan Building

Groundwater heat pump

6.05

40,000

Beijing Daxing international airport

Ground-coupled heat pump

54.2

17,000

Tianhu International Conference hotel

Ground-coupled heat pump

–

40.000

Beijing contemporary world city

Ground-coupled heat pump

4.8

220,000

Expo axis

Ground-coupled heat pump

–

250,000