Table 6 Results of the proposed positioning method (φ = 30∘, ungrounded system)

From: A novel fault section locating method based on distance matching degree in distribution network

Rg/Ω

F

HSAB

HSBC

HSCD

HSDE

HSEF

section

0

F1

0.4198

/

/

/

/

AB

F2

0.9873

0.4572

/

/

/

BC

F3

0.9860

0.9892

0.4334

/

/

CD

F4

0.9865

0.9895

0.9940

0.4628

/

DE

F5

0.9861

0.9881

0.9923

0.9914

0.4988

EF

100

F1

0.4313

/

/

/

/

AB

F2

0.9871

0.4516

/

/

/

BC

F3

0.9866

0.9901

0.4617

/

/

CD

F4

0.9869

0.9900

0.9943

0.4693

 

DE

F5

0.9867

0.9898

0.9943

0.9930

0.4699

EF

500

F1

0.4264

/

/

/

/

AB

F2

0.9866

0.4489

/

/

/

BC

F3

0.9758

0.9892

0.4613

/

/

CD

F4

0.9866

0.9894

0.9921

0.4721

/

DE

F5

0.9867

0.9895

0.9923

0.9898

0.4770

EF