Skip to main content

Table 5 Comparison of the line selection criterias

From: Fault protection method of single-phase break for distribution network considering the influence of neutral grounding modes

Fault location (km)Negative sequence current(A)Sequence current changes ratio
0450.61.0
2350.31.0
4253.51.0
6163.21.0
878.91.0
1074.61.0