Skip to main content

Articles

Page 5 of 7

  1. The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In ...

    Authors: Bin Li, Jiawei He, Ye Li and Botong Li
    Citation: Protection and Control of Modern Power Systems 2019 4:21
  2. In view of the operating characteristics for voltage sags of AC side of the power electronic transformer(PET), a low-voltage ride through(LVRT) strategy adapted to bidirectional power exchange of PET is propos...

    Authors: Jiexiang Han, Xiangping Kong, Peng Li, Zhe Zhang and Xianggen Yin
    Citation: Protection and Control of Modern Power Systems 2019 4:20
  3. This article explores and establishes comprehensive evaluation index system of wind power accommodation ability considering microscopic index and macroscopic index, and the index system includes conventional e...

    Authors: Gengyin Li, Guodong Li and Ming Zhou
    Citation: Protection and Control of Modern Power Systems 2019 4:19
  4. This article presents the direct torque control (DTC) strategy for the doubly fed induction motor (DFIM) connected to two three-level voltage source inverters (3LVSIs) with neutral point clamped (NPC) structur...

    Authors: Najib El Ouanjli, Aziz Derouich, Abdelaziz El Ghzizal, Mohammed Taoussi, Youness El Mourabit, Khalid Mezioui and Badre Bossoufi
    Citation: Protection and Control of Modern Power Systems 2019 4:17
  5. Load frequency control (LFC) in today’s modern power system is getting complex, due to intermittency in the output power of renewable energy sources along with substantial changes in the system parameters and ...

    Authors: Anil Annamraju and Srikanth Nandiraju
    Citation: Protection and Control of Modern Power Systems 2019 4:16
  6. This paper presents an annual performance evaluation of three maximum power point tracking (MPPT) methods. The used MPPT techniques (Perturb and Observe, Incremental Inductance and Sliding mode) are evaluated ...

    Authors: Y. Chaibi, A. Allouhi, M. Salhi and A. El-jouni
    Citation: Protection and Control of Modern Power Systems 2019 4:15
  7. Multi-microgrids have many new characteristics, such as bi-directional power flow, flexible operation and variable fault current consisting of the different control strategy of inverter interfaced distributed ...

    Authors: Fan Zhang and Longhua Mu
    Citation: Protection and Control of Modern Power Systems 2019 4:14
  8. The rapid development of Internet Plus Smart Energy requires further strengthening of three kinds of interconnections based on traditional power systems: physical interconnection, information interconnection, ...

    Authors: Haoyong Chen, Xiaojuan Wang, Zhihao Li, Wutao Chen and Yongzhi Cai
    Citation: Protection and Control of Modern Power Systems 2019 4:13
  9. In the traditional power system demand response, customers respond to electricity price or incentive and change their original power consumption pattern accordingly to gain additional benefits. With the develo...

    Authors: Wujing Huang, Ning Zhang, Chongqing Kang, Mingxuan Li and Molin Huo
    Citation: Protection and Control of Modern Power Systems 2019 4:12
  10. Conventional direct torque control (DTC) is one of the excellent control strategies available to control the torque of the induction machine (IM). However, the low switching frequency of the DTC causes high ri...

    Authors: Najib El Ouanjli, Aziz Derouich, Abdelaziz El Ghzizal, Saad Motahhir, Ali Chebabhi, Youness El Mourabit and Mohammed Taoussi
    Citation: Protection and Control of Modern Power Systems 2019 4:11
  11. Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which b...

    Authors: Senthil Krishnamurthy and Bwandakassy Elenga Baningobera
    Citation: Protection and Control of Modern Power Systems 2019 4:10
  12. Heavy fault currents flow in the event of fault at the loads connected in distribution system. To protect these loads, circuit breakers and relays are required at appropriate places with proper coordination be...

    Authors: Sarang V. Khond and Gunwant A. Dhomane
    Citation: Protection and Control of Modern Power Systems 2019 4:9
  13. This paper describes the usefulness of renewable energy throughout the world to generate power. Renewable energy adds a remarkable scope in power system. Renewable energy sources act as the prime mover of a mi...

    Authors: Faisal R. Badal, Purnima Das, Subrata K. Sarker and Sajal K. Das
    Citation: Protection and Control of Modern Power Systems 2019 4:8
  14. This work considers the problem of decentralized control of inverter-based ac micro-grid in different operation modes. The main objectives are to (i) design decentralized frequency and voltage controllers, to gat...

    Authors: Mehdi Farokhian Firuzi, Alireza Roosta and Mohsen Gitizadeh
    Citation: Protection and Control of Modern Power Systems 2019 4:6
  15. In this paper, a particular standard MicroGrid (MG) is accurately simulated in the presence of the Electric Vehicles (EVs) participating in decentralized primary frequency control service. It examines effect o...

    Authors: Mahdi Bayati, Mehrdad Abedi, Gevork B. Gharehpetian and Maryam Farahmandrad
    Citation: Protection and Control of Modern Power Systems 2019 4:5
  16. Increased penetration of wind energy systems has serious concerns on power system stability. In spite of several advantages, doubly fed induction generator (DFIG) based wind energy systems are very sensitive t...

    Authors: Tummala S. L. V. Ayyarao
    Citation: Protection and Control of Modern Power Systems 2019 4:4
  17. The role of Power System Stabilizer (PSS) in the power system is to provide necessary damping torque to the system in order to suppress the oscillations caused by a variety of disturbances that occur frequentl...

    Authors: Butti Dasu, Mangipudi Sivakumar and Rayapudi Srinivasarao
    Citation: Protection and Control of Modern Power Systems 2019 4:2
  18. At present, the problem of abandoning wind and PV power in “Three North” region of China is particularly significant, and how to alleviate this problem has become the focus of universal attention. Calculation ...

    Authors: Guodong Li, Gengyin Li and Ming Zhou
    Citation: Protection and Control of Modern Power Systems 2019 4:1
  19. With rapidly growing of Renewable Energy Sources (RESs) in renewable power systems, several disturbances influence on the power systems such as; lack of system inertia that results from replacing the synchrono...

    Authors: Gaber Magdy, G. Shabib, Adel A. Elbaset and Yasunori Mitani
    Citation: Protection and Control of Modern Power Systems 2018 3:39
  20. For maximum utilization of solar energy, photovoltaic (PV) power systems should be operated at the maximum power point (MPP) which can be achieved using maximum power point tracking (MPPT) methods. However, th...

    Authors: Liqun Shang, Weiwei Zhu, Pengwei Li and Hangchen Guo
    Citation: Protection and Control of Modern Power Systems 2018 3:38
  21. The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements. Such a complex network is susceptible to faults caused due to several reas...

    Authors: Bhargav Appasani and Dusmanta Kumar Mohanta
    Citation: Protection and Control of Modern Power Systems 2018 3:37
  22. Current and voltage waveforms recorded by intelligent electronic devices (IEDs) are more useful than just performing post-fault analysis. The objective of this paper is to present techniques to estimate the ze...

    Authors: Swagata Das, Sundaravaradan Navalpakkam Ananthan and Surya Santoso
    Citation: Protection and Control of Modern Power Systems 2018 3:36
  23. Three-phase pulse width modulation converters using insulated gate bipolar transistors (IGBTs) have been widely used in industrial application. However, faults in IGBTs can severely affect the operation and sa...

    Authors: Yang Xia, Bin Gou and Yan Xu
    Citation: Protection and Control of Modern Power Systems 2018 3:33
  24. In this paper, a sensitivity matrix based approach is proposed to improve the minimum damping ratio. The proposed method also avoids burdensome deviation calculations of damping ratio of large-scale power grid...

    Authors: Yude Yang, Jixing Zhao, Hui Liu, Zhijun Qin, Jun Deng and Junjian Qi
    Citation: Protection and Control of Modern Power Systems 2018 3:34
  25. High penetration of Converter Interfaced Generations (CIGs) presents challenges in both microgrid (μGrid) circuit and other system with CIG resources, such as wind farms and PV plants. Specifically, protection...

    Authors: Y. Liu, A. P. Meliopoulos, L. Sun and S. Choi
    Citation: Protection and Control of Modern Power Systems 2018 3:31
  26. This paper proposes a novel controllable crowbar based on fault type (CBFT) protection technique for doubly fed induction generator (DFIG) wind energy conversion system connected to grid. The studied system co...

    Authors: Omar Noureldeen and I. Hamdan
    Citation: Protection and Control of Modern Power Systems 2018 3:35
  27. The simulation precision of the classic load model (CLM) is affected by the increasing proportion of installed energy storage capacity in the grid. This paper studies the all-vanadium redox flow battery (VRB) ...

    Authors: L Zhou, Z W Peng, C R Deng, X Z Qi and P Q Li
    Citation: Protection and Control of Modern Power Systems 2018 3:32
  28. There is growing interest in power quality issues due to wider developments in power delivery engineering. In order to maintain good power quality, it is necessary to detect and monitor power quality problems....

    Authors: S. Asha Kiranmai and A. Jaya Laxmi
    Citation: Protection and Control of Modern Power Systems 2018 3:29
  29. High resistance fault poses an enormous challenge to the existing algorithms of fault detection and fault classification. In this paper, the standard deviation and accumulation method are employed to perform t...

    Authors: Mohammed H. H. Musa, Zhengyou He, Ling Fu and Yujia Deng
    Citation: Protection and Control of Modern Power Systems 2018 3:30
  30. High quality electric power supply is the prime goal in the modern power systems around the world. One of the main ways to achieve this is the protection of the system which needs to be fast, reliable and cost...

    Authors: S. Gopiya Naik, Vibin Ravi and Ramya Arshiya
    Citation: Protection and Control of Modern Power Systems 2018 3:28
  31. Grid resource utilization rate plays a key role in power grid operation. Although the proportion of population and the area in China Southern Power Grid (CSG) and National Grid Plc of UK (NG) are nearly, grid ...

    Authors: Long Zhou, Di Zhang, Weijie Wu, Manman Zhu, Hanyu Yang, Canbing Li, Ge Li, Fei Li and Mingjian Cui
    Citation: Protection and Control of Modern Power Systems 2018 3:26
  32. This paper proposes a residue theorem based soft sliding mode control strategy for a permanent magnet synchronous generator (PMSG) based wind power generation system (WPGS), to achieve the maximum energy conve...

    Authors: Mohammed Alsumiri, Liuying Li, Lin Jiang and Wenhu Tang
    Citation: Protection and Control of Modern Power Systems 2018 3:24
  33. This paper presents a coordination strategy of Load Frequency Control (LFC) and digital frequency protection for an islanded microgrid (MG) considering high penetration of Renewable Energy Sources (RESs). In s...

    Authors: G. Magdy, Emad A. Mohamed, G. Shabib, Adel A. Elbaset and Yasunori Mitani
    Citation: Protection and Control of Modern Power Systems 2018 3:23
  34. Event reports recorded by intelligent electronic devices (IEDs) such as digital relays and fault recorders during disturbances depict the status and system parameters of the power system. Incorrect relay setti...

    Authors: Swagata Das, Sundaravaradan Navalpakkam Ananthan and Surya Santoso
    Citation: Protection and Control of Modern Power Systems 2018 3:22
  35. This paper presents an enhanced control strategy for Wind Energy Conversion System (WECS) using Doubly-Fed Induction Generator (DFIG). A robust Super-Twisting (STW) sliding mode control for variable speed wind...

    Authors: Saïd Boubzizi, Hafedh Abid, Ahmed El hajjaji and Mohamed Chaabane
    Citation: Protection and Control of Modern Power Systems 2018 3:21
  36. To deal with the high dimensionality and computational density of the Optimal Power Flow model with Transient Stability Constraints (OTS), a credible criterion to determine transient stability is proposed base...

    Authors: Yude Yang, Anjun Song, Hui Liu, Zhijun Qin, Jun Deng and Junjian Qi
    Citation: Protection and Control of Modern Power Systems 2018 3:20
  37. The recent development of phasor measurement technique opens the way for real-time post-disturbance transient stability assessment (TSA). Following a disturbance, since the transient instability can occur very...

    Authors: Chao Ren, Yan Xu and Yuchen Zhang
    Citation: Protection and Control of Modern Power Systems 2018 3:19
  38. The economy of distribution networks largely depends on the utilization rate of distribution network equipment. Most of the emerging intelligent power consumption technologies have a positive effect on equipme...

    Authors: Yuqing He, Yuehui Chen, Zhiqiang Yang, Hongbin He and Li Liu
    Citation: Protection and Control of Modern Power Systems 2018 3:18
  39. Remote monitoring of transmission lines of a power system is significant for improved reliability and stability during fault conditions and protection system breakdowns. This paper proposes a smart backup moni...

    Authors: Pathirikkat Gopakumar, Balimidi Mallikajuna, Maddikara Jaya Bharata Reddy and Dusmanta Kumar Mohanta
    Citation: Protection and Control of Modern Power Systems 2018 3:16
  40. Big data technology is more and more widely used in modern power systems. Efficient collection of big data such as equipment status, maintenance and grid operation in power systems, and data mining are the imp...

    Authors: Zhuangli Hu, Tong He, Yihui Zeng, Xiangyuan Luo, Jiawen Wang, Sheng Huang, Jianming Liang, Qinzhang Sun, Hengbin Xu and Bin Lin
    Citation: Protection and Control of Modern Power Systems 2018 3:15
  41. The large-scale popularization of electric vehicles (EVs) brings the potential for grid frequency regulation. Considering the characteristics of fast response and adjustment of EVs, two control strategies of a...

    Authors: H. Liu, K. Huang, Y. Yang, H. Wei and S. Ma
    Citation: Protection and Control of Modern Power Systems 2018 3:13
  42. This paper proposes Phasor Measurement Unit (PMU) based adaptive zone settings of distance relays (PAZSD) methodology for protection of multi-terminal transmission lines (MTL). The PAZSD methodology employs cu...

    Authors: Balimidi Mallikarjuna, Pudi Shanmukesh, Dwivedi Anmol, Maddikara Jaya Bharata Reddy and Dusmanta Kumar Mohanta
    Citation: Protection and Control of Modern Power Systems 2018 3:12
  43. Stable and safe operation of power grids is an important guarantee for economy development. Support Vector Machine (SVM) based stability analysis method is a significant method started in the last century. How...

    Authors: Kaiyuan Hou, Guanghui Shao, Haiming Wang, Le Zheng, Qiang Zhang, Shuang Wu and Wei Hu
    Citation: Protection and Control of Modern Power Systems 2018 3:11
  44. Parallel operation of inverter modules is the solution to increase the reliability, efficiency, and redundancy of inverters in microgrids. Load sharing among inverters in distributed generators (DGs) is a key ...

    Authors: Suleman Haider, Guojie Li and Keyou Wang
    Citation: Protection and Control of Modern Power Systems 2018 3:10