Skip to main content

Table 3 Specification of IM used

From: A robust principal component analysis-based approach for detection of a stator inter-turn fault in induction motors

Symbol

Quantity

Value

\(P_{n}\)

Nominal power

1 \({\text{KW}}\)

\(V_{abc}\)

Rated voltage

220 \({\text{V}}\)

\(I_{abc}\)

Rated current

3.6 \({\text{A}}\)

\(f_{s}\)

Rated frequency

50 \({\text{Hz}}\)

\(cos\left( \emptyset \right)\)

Rated power factor

0.74

\(J\)

Rotor inertia

0.0025 \({\text{Kg m}}^{2}\)

\(P\)

Number of poles

4

\(\omega_{r}\)

No load speed

145.0368 \({\text{rad}}/{\text{s}}\)

\(R_{s}\)

Stator winding resistance

8.4 \(\Omega\)

\(R_{r}\)

Referred rotor winding resistance

8.2 \(\Omega\)

\(L_{ls}\)

Stator winding leakage inductance

32.78 \({\text{mH}}\)

\(L_{lr}\)

Referred rotor winding leakage inductance

32.78 \({\text{mH}}\)

\(L_{m}\)

Magnetizing inductance

437.67 \({\text{mH}}\)