Table 3 Dynamic parameters of the SMES control loop

From: Superconducting energy storage technology-based synthetic inertia system control to enhance frequency dynamic performance in microgrids with high renewable penetration

Parameters

Value

Feedback gain of the inductor current deviation, Kf

0.001

Time delay of the converter, Tc (s)

0.030

Current of SMES coil, Id0 (kA)

1.732

Coil inductance, L (H)

3.000

SMES control gain, KSMES