Table 2 Parameters of the simulated system

From: Model predictive control of grid-connected PV power generation system considering optimal MPPT control of PV modules

Parameters of the PV module

value

Parameters of the system

value

\(S\)/W·m−2

1000

\(P\)/W

0.35 × 104

\(T\)/℃

25

\(f\)/Hz

60

\(U_{{{\text{oc}}}}\)/V

85.40

\(C_{{{\text{dc}}}}\)/F

0.06

\(I_{{{\text{sc}}}}\)/A

6.09

\(L\)/H

0.01 × 10–6

\(U_{{\text{m}}}\)/V

72.90

\(R\)/Ω

0.03 × 10–6

\(I_{{\text{m}}}\)/A

5.69

\(U_{{{\text{dc}}}}\)/V

480

\(N_{{\text{s}}}\)

7

\(P_{{{\text{T1}}}}\)/VA

0.25 × 106

\(N_{{\text{p}}}\)

88

\(P_{{{\text{T2}}}}\)/VA

0.50 × 108