Skip to main content

Table 2 Parameters of the simulated system

From: Model predictive control of grid-connected PV power generation system considering optimal MPPT control of PV modules

Parameters of the PV module value Parameters of the system value
\(S\)/W·m−2 1000 \(P\)/W 0.35 × 104
\(T\)/℃ 25 \(f\)/Hz 60
\(U_{{{\text{oc}}}}\)/V 85.40 \(C_{{{\text{dc}}}}\)/F 0.06
\(I_{{{\text{sc}}}}\)/A 6.09 \(L\)/H 0.01 × 10–6
\(U_{{\text{m}}}\)/V 72.90 \(R\) 0.03 × 10–6
\(I_{{\text{m}}}\)/A 5.69 \(U_{{{\text{dc}}}}\)/V 480
\(N_{{\text{s}}}\) 7 \(P_{{{\text{T1}}}}\)/VA 0.25 × 106
\(N_{{\text{p}}}\) 88 \(P_{{{\text{T2}}}}\)/VA 0.50 × 108