Skip to main content

Table 1 List of cases for a 2 × 2 PV array under shading combinations with voltage regions

From: Stochastic maximum power point tracking of photovoltaic energy system under partial shading conditions

Case No

Module conditions \({(Wm}^{-2}\))

\({V}_{pv}\)

\({M}_{P}\)

\({I}_{PV}\)

Case 1

No one shaded(1000)

52.47

799.2

15.2315

 

One Module Shaded shaded(200)

53.19

483.3

9.0862

 

Two Module shaded(200)

52.01

471.2

9.0597

 

Three Module shaded(200)

26.63

242.4

9.1025

 

Four Module shaded(200)

49.87

147.5

2.9576

Case 2

No one shaded(900)

52.66

718.4

13.6422

 

One Module shaded(300)

53.36

486.1

9.1098

 

Two Module shaded(300)

52.14

472.3

9.0583

 

Three Module shaded(300)

26.95

244.1

9.0575

 

Four Module shaded(300)

50.45

187.5

3.7165

Case 3

No one shaded(500)

51.86

391.8

7.5549

 

One Module shaded(250)

52.62

299.2

5.6860

 

Two Module shaded(250)

51.41

289.2

5.6253

 

Three Module shaded(250)

52.17

195.8

3.7531

Case 4

No one shaded(700)

52.45

555.8

10.5967

Case 5

Module 4 shaded(250)

53.44

505

9.4498

Case 6

Module 2&3 shaded(200)

26.3

399.1

15.1749

Case 7

Module 1&4 shaded(200)

26.3

399.1

15.1749

Case 8

Module 1&3 shaded(200)

26.3

399.1

15.1749

Case 9

Module 2 shaded(200)

53.23

483.3

9.0794