Table 1 idref and iqref under different operating conditions

From: Equivalent model of multi-type distributed generators under faults with fast-iterative calculation method based on improved PSO algorithm

Criterions

idref

iqref

Vpcc > 0.9

idref =  id0ref

iqref  =  0

0.2 < Vpcc < 0.9 and \(i_{qref} \le \sqrt {I_{\max }^{2} - i_{d0ref}^{2} }\)

idref  =  id0ref

iqref  =  α∙(m-Vpcc)

0.2 < Vpcc < 0.9 and \(i_{qref} > \sqrt {I_{\max }^{2} - i_{d0ref}^{2} }\)

idref  =  \(\sqrt {I_{\max }^{2} - i_{qref \, }^{2} }\)

iqref  =  α∙(m-Vpcc)