Skip to main content

Table 4 Quantitative assessment of steady state performance at Unity PF (Pref = 10 kW, Qref = 0 VAR)

From: High performance decoupled active and reactive power control for three-phase grid-tied inverters using model predictive control

Parameter

Value

Average value of active power

PAVG [W]

9990

Worst value of active power ripple

∆P = (Pref - Pactual) [W]

422

Percentage of active power ripple

100x∆P/Pref) [%]

4.22

Percentage of active power deviation

100 x (Pref - PAVG)/Pref [%]

0.10

Average value of reactive power

QAVG [VAR]

68

Worst value of reactive power ripple

∆Q = (Qref - Qactual [VAR]

529

Actual PF

Cos [tan−1(Q/P)]

0.999

Total harmonic distortion

THD of grid current [%]

3.35