Skip to main content

Table 3 Energy flow of the natural gas system

From: An integrated multi-energy flow calculation method for electricity-gas-thermal integrated energy systems

Node number Node pressure/bar Pipe number Gas flow/m3/h
1 5.000 1 7233.8
2 4.579 2 4333.8
3 4.566 3 1100.0
4 4.551 4 1800.0
5 3.874 5 4318.0
6 4.862 6 2310.0
7 4.627   
8 4.581   
  1. Note: Natural gas consumption of the compressor is 19.8015 m3/h, the compressor compression ratio is 1.2551