Skip to main content

Table 2 Energy flow of the thermal system

From: An integrated multi-energy flow calculation method for electricity-gas-thermal integrated energy systems

Node number Supply temperature/°C Return temperature/°C Pipe number Flow/kg/s
1 99.3364 37.6222 1 7.1516
2 99.4534 37.7599 2 6.9510
3 90.4096 40.0000 3 0.2362
4 99.5624 37.9148 4 6.5146
5 99.2964 37.6206 5 3.3722
6 87.5374 40.0000 6 0.2504
7 99.1285 37.8390 7 2.7202
8 93.7532 40.0000 8 0.2215
9 99.0363 38.2022 9 2.4585
10 98.6712 38.4412 10 2.1360
11 90.4096 40.0000 11 0.2362
12 98.1056 39.1189 12 1.4939
13 96.2674 40.0000 13 1.2890
14 100.0 37.3725 14 2.9425