Skip to main content

Table 1 Real-time simulation parameters

From: FPGA-based real-time simulation for EV station with multiple high-frequency chargers based on C-EMTP algorithm

Parameter Unit Value
AC power grid Vg V 220
Filter inductor of rectifier Lg and Lf mH 1
Filter capacitor of rectifier Cf μF 100
Capacitor on DC bus Cdc μF 800
Leakage inductance of transformer L μH 160
Transformer ratio NT / 2:1
Output filter capacitor Co μF 800
DC bus rated voltage Vdc V 800
Output Voltage Vo V 300–500
Output power Po kW 0–8
Rectifier switching frequency kHz 10
DAB switching frequency kHz 50