Skip to main content

Table 2 Transient voltage parameters under different algorithms and load disturbances

From: Stability enhancement of wind energy integrated hybrid system with the help of static synchronous compensator and symbiosis organisms search algorithm

Input conditions

Applied algorithms

Peak time (tp)

Rise time (tr)

Steady state error (Ess)

Overshoot (Mp)

FOD

V = 0.97, Xeq = 1.08

GSA

10.000

9.9971

0.0104

0.0259

−0.8795

BGA

0.2340

0.1849

0.0104

0.0259

1.3257

SOS

0.2500

0.1968

0.0065

0.0266

1.3206

V = 1.0, Xeq = 0.93

GSA

10.0000

9.9974

0.0078

0.0083

−0.8795

BGA

0.2344

0.1858

0.0100

0.0269

1.3260

SOS

0.2548

0.2016

0.0066

0.0240

1.3175