From: Direct torque control of doubly fed induction motor using three-level NPC inverter
Flux | 1 | −1 | 0 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque | 2 | 1 | 0 | -1 | −2 | 2 | 1 | 0 | −1 | −2 | 2 | 1 | 0 | −1 | −2 | |
Sectors (Si) | S1: [−15°,15°] | V21 | V21 | V0 | V26 | V26 | V17 | V3 | V0 | V5 | V19 | V22 | V22 | V0 | V25 | V25 |
S2: [15°,45°] | V16 | V2 | V7 | V1 | V15 | V23 | V23 | V7 | V25 | V25 | V17 | V3 | V7 | V6 | V20 | |
S3: [45°,75°] | V22 | V22 | V14 | V21 | V21 | V18 | V4 | V14 | V6 | V20 | V23 | V23 | V14 | V26 | V26 | |
S4: [75°,105°] | V17 | V3 | V0 | V2 | V16 | V24 | V24 | V0 | V26 | V26 | V18 | V4 | V0 | V1 | V15 | |
S5: [105°,135°] | V23 | V23 | V7 | V22 | V22 | V19 | V5 | V7 | V1 | V15 | V24 | V24 | V7 | V21 | V21 | |
S6: [135°,165°] | V18 | V4 | V14 | V3 | V17 | V25 | V25 | V14 | V21 | V21 | V19 | V5 | V14 | V2 | V16 | |
S7: [165°,195°] | V24 | V24 | V0 | V23 | V23 | V20 | V6 | V0 | V2 | V16 | V25 | V25 | V0 | V22 | V22 | |
S8: [195°,225°] | V19 | V5 | V7 | V4 | V18 | V26 | V26 | V7 | V22 | V22 | V20 | V6 | V7 | V3 | V17 | |
S9: [225°,255°] | V25 | V25 | V14 | V24 | V24 | V15 | V1 | V14 | V3 | V17 | V26 | V26 | V14 | V23 | V23 | |
S10: [255°,285°] | V20 | V6 | V0 | V5 | V19 | V21 | V21 | V0 | V23 | V23 | V15 | V1 | V0 | V4 | V18 | |
S11: [285°,315°] | V26 | V26 | V7 | V25 | V25 | V16 | V2 | V7 | V4 | V18 | V21 | V21 | V7 | V24 | V24 | |
S12: [315°,345°] | V15 | V1 | V14 | V6 | V20 | V22 | V22 | V14 | V24 | V24 | V16 | V2 | V14 | V5 | V19 |