From: Direct torque control of doubly fed induction motor using three-level NPC inverter
Flux | 0 | 1 | |||||
---|---|---|---|---|---|---|---|
Torque | − 1 | 0 | 1 | −1 | 0 | 1 | |
Sectors (Si) | S1: [−30°, 30°] | V5 | V0 | V3 | V6 | V7 | V2 |
S2: [30°,90°] | V6 | V7 | V4 | V1 | V0 | V3 | |
S3: [90°,150°] | V1 | V0 | V5 | V2 | V7 | V4 | |
S4: [150°,210°] | V2 | V7 | V6 | V3 | V0 | V5 | |
S5: [210°,270°] | V3 | V0 | V1 | V4 | V7 | V6 | |
S6: [270°,330°] | V4 | V7 | V2 | V5 | V0 | V1 |