Skip to main content

Advertisement

Table 3 Dynamic performance of the proposed controller with & without EVs

From: Robust frequency control in a renewable penetrated power system: an adaptive fractional order-fuzzy approach

Controller Case 2
Peak Over shoot (Hz) Settling Time (sec)
Adaptive FO-Fuzzy-PID without EVs 0.088 27
Adaptive FO-Fuzzy-PID with EVs 0.025 13