Skip to main content

Table 2 Performance of fault detection, fault time at Rf value of different location in line

From: A critical fault detection analysis & fault time in a UPFC transmission line

Types Of Fault

Rf in Ω

Fault Location In km

FIA in degree

Power angle in degree

SE based S-T fault time in cycle period [24]

WT based fault time in cycle period [25]

Proposed fault time in cycle period

ABC

10

60

30

45

1.23

1.53

Ë‚ 1

ABC

100

170

45

60

1.24

1.54

Ë‚ 1

ABCG

20

50

45

60

1.25

1.55

Ë‚ 1

ABCG

100

160

60

45

1.23

1.53

Ë‚ 1

ABG

10

85

90

60

1.25

1.55

Ë‚ 1

BCG

50

120

45

45

1.25

1.55

Ë‚ 1

CAG

100

180

60

60

1.24

1.54

Ë‚ 1