From: Parallel computing of multi-contingency optimal power flow with transient stability constraints
Number of Contingencies | NE39 | IEEE300 | C703 | |||
---|---|---|---|---|---|---|
Speed-up Ratio | Efficiency | Speed-up Ratio | Efficiency | Speed-up Ratio | Efficiency | |
2 | 0.73 | 0.37 | 1.21 | 0.61 | 1.30 | 0.65 |
4 | 1.20 | 0.30 | 2.00 | 0.50 | 2.16 | 0.54 |
6 | 1.60 | 0.27 | 2.60 | 0.43 | 2.90 | 0.48 |
8 | 2.03 | 0.25 | 3.18 | 0.40 | 3.62 | 0.45 |
10 | 2.25 | 0.23 | 4.05 | 0.40 | 4.45 | 0.45 |
12 | 2.58 | 0.22 | 5.17 | 0.43 | 4.81 | 0.40 |
14 | 2.84 | 0.20 | 4.67 | 0.33 | 5.40 | 0.39 |
16 | 3.22 | 0.20 | 5.14 | 0.32 | 5.84 | 0.36 |
18 | 3.32 | 0.18 | 5.43 | 0.30 | 5.90 | 0.33 |
20 | 3.54 | 0.18 | 6.36 | 0.32 | 6.42 | 0.32 |
22 | 3.62 | 0.16 | 5.94 | 0.27 | 6.93 | 0.31 |
24 | 4.12 | 0.17 | 7.04 | 0.29 | 7.27 | 0.30 |
26 | 4.05 | 0.16 | 7.36 | 0.28 | 7.36 | 0.28 |
28 | 4.49 | 0.16 | 7.57 | 0.27 | 7.26 | 0.26 |
30 | 4.83 | 0.16 | 7.11 | 0.24 | 7.27 | 0.24 |
32 | 4.85 | 0.15 | 7.27 | 0.23 | 7.28 | 0.23 |