Table 1 Voltage errors between the actual and estimated values with and without considering capacity loss

From: Modeling and SOC estimation of lithium iron phosphate battery considering capacity loss

SOC

(0,0.3)

(0.3,0.7)

(0.7,1)

Voltage error without considering capacity loss

0.3–0.4 V

0–0.03 V

0–0.1 V

Voltage error considering capacity loss

0–0.1 V

0–0.02 V

0–0.02 V