Skip to main content

Table 6 Results obtained from ODE of test system 2 of fixed head hydrothermal system

From: Opposition-based differential evolution for hydrothermal power system

Sub-interval Ρ h1 (MW) Ρ h2 (MW) Ρ s1 (MW) Ρ s2 (MW) Ρ s3 (MW) Ρ s4 (MW)
1 172.6478 317.8272 93.6207 174.7438 109.2596 50.3779
2 243.8370 411.3216 124.8716 174.6929 123.6025 50.1150
3 209.7780 351.8750 116.1764 174.7282 120.3243 50.0519
4 249.8641 499.8741 124.8642 174.9127 222.4536 68.0992