Skip to main content

Table 21 Optimal Hydro Discharge (× 104 m 3) for case 2 of test system 1 of variable head hydrothermal system

From: Opposition-based differential evolution for hydrothermal power system

Hour Q h1 Q h2 Q h3 Q h4
1 10.1845 6.1121 20.5536 6.3438
2 9.3545 6.0000 29.9857 6.0059
3 5.0934 6.0672 18.8188 6.0081
4 12.3025 6.9922 19.7814 6.0011
5 9.4396 6.9832 15.2970 6.3376
6 7.8835 6.3622 18.4255 11.1545
7 10.2721 8.2105 18.0212 8.7499
8 6.7694 6.0283 17.9212 9.3215
9 6.6014 6.9949 16.6465 15.9994
10 9.8394 6.6298 14.1732 14.6373
11 5.8365 8.0881 17.9684 19.8695
12 6.2467 6.7252 18.3894 15.9965
13 10.4311 6.0065 16.4035 15.9976
14 6.7118 6.0342 19.8262 13.0358
15 5.2117 8.9019 14.7661 19.6512
16 5.8669 8.0785 18.5218 18.0045
17 10.3436 13.0473 15.8221 18.0241
18 9.0289 8.2601 15.6486 18.1861
19 6.8068 10.6257 18.4059 18.1376
20 5.0351 13.1212 10.7805 18.6221
21 7.2673 9.9088 11.9574 18.0174
22 7.0480 12.8178 11.9622 20.0000
23 7.9655 10.0050 10.1140 19.8378
24 13.2600 13.2228 11.6386 19.6248