Skip to main content

Table 20 Optimal Hydrothermal generation (MW) for case 1 of test system 1 of variable head hydrothermal system

From: Opposition-based differential evolution for hydrothermal power system

Hour Ρ h1 Ρ h2 Ρ h3 Ρ h4 Ρ s
1 79.7973 49.0061 0 131.8801 1109.32
2 79.3927 50.1639 43.5292 129.0270 1087.89
3 79.0387 51.2957 0 125.7437 1103.92
4 77.7373 52.9380 37.4242 121.6365 1000.26
5 75.9674 54.4995 42.2628 115.8283 1001.44
6 74.6619 55.5248 42.0011 163.8960 1073.92
7 74.9610 56.6535 42.7802 209.7731 1265.83
8 76.6787 62.1650 41.6644 252.8746 1566.62
9 77.7838 65.9683 41.8104 271.8340 1782.60
10 79.1114 67.7564 40.9661 278.4111 1853.75
11 78.7489 68.9033 38.9557 275.1930 1768.19
12 80.1994 71.5905 39.5975 282.2694 1836.34
13 79.6781 72.1369 38.3010 281.2003 1758.68
14 79.2573 72.8195 38.1722 282.2342 1727.52
15 79.5884 73.6734 35.5391 286.6439 1654.55
16 78.9796 75.6289 36.7765 284.1818 1594.43
17 78.8516 76.9618 41.8592 288.8606 1643.46
18 77.9593 78.3512 45.1334 291.6388 1646.92
19 77.8291 79.6915 48.4354 298.8079 1735.23
20 77.0919 80.4924 50.2710 303.4720 1768.67
21 75.8005 81.3147 51.4605 304.7025 1726.72
22 74.1001 81.9619 53.9109 301.5554 1608.47
23 71.1238 82.8437 56.0420 297.2275 1342.77
24 69.4655 81.8843 57.7491 291.3201 1089.58