Table 14 Thermal generator data of test system 1
From:
Opposition-based differential evolution for hydrothermal power system
Unit
\( {P}_s^{\min } \)
\( {P}_s^{\max } \)
a
s
b
s
c
s
d
s
e
s
MW
MW
$/h
$/MWh
$/(MW)2 h
$/h
1/MW
1
50
300
25
3.2
0.0025
0
0
2
50
700
30
3.4
0.0008
0
0